MatLMVMSymBadBroydenSetPsi#
Get the psi parameter for a Broyden class quasi-Newton update matrix
Synopsis#
#include "petscksp.h"
PetscErrorCode MatLMVMSymBadBroydenSetPsi(Mat B, PetscReal psi)
Input Parameters#
B - The matrix
psi - a number defining an update that is a convex combination of the BFGS update (psi = 1) and DFP update (psi = 0)
Note#
If B cannot have a constant value of psi for all iterations this will
be ignored.
This is the case if B is a MATLMVMSYMBROYDEN, where psi’s dual value
phi is constant and psi changes from iteration to iteration.
See Also#
KSP: Linear System Solvers,
MATLMVMSYMBROYDEN, MATLMVMSYMBADBROYDEN,
MATLMVMDFP, MATLMVMBFGS,
MatLMVMSymBadBroydenGetPsi(),
MatLMVMSymBroydenGetPhi(), MatLMVMSymBroydenSetPhi()
Level#
developer
Location#
src/ksp/ksp/utils/lmvm/symbrdn/symbrdn.c