PCAIRSetFullSmoothingUpAndDown#

Sets whether PCAIR smooths all points on the up and down sweeps, instead of the default down F and C smoothing

Synopsis#

Logically Collective

Input Parameters#

  • pc - the PCAIR preconditioner context

  • input_bool - PETSC_TRUE to smooth all points on both the up and down sweeps

Options Database Key#

  • -pc_air_full_smoothing_up_and_down (true|false) - smooth all points up and down, instead of the default down F and C smoothing; defaults to false

Note#

By default PCAIR only smooths on the way down the hierarchy (the reduction-multigrid F and C smooths); enabling this smooths all points on both the up and down sweeps, which resembles a standard multigrid cycle and can be more robust for some problems at a higher cost per cycle.

See Also#

KSP: Linear System Solvers, PCAIR, PCAIRGetFullSmoothingUpAndDown(), PCAIRSetSmoothType()

Level#

advanced

Index of all PC routines
Table of Contents for all manual pages